Question:
Can you configure the NetSoft Emulators for operation as a DOWN
STREAM PHYSICAL UNIT (DSPU) off the MICROSOFT NT SNA Server Gateway
Facility.
Answer: Yes, select 802.2 LLC or
SDLC from the LINK DRIVER Selection Menu and provide required configuration
parameters I.E. PU ADDR, Destination Adapter Address, Logical Units
to be managed etc......
Question: Do your Emulators have the ability to support 56kb
line speeds via DIRECT SDLC Connection.
Answer: Yes, Contact NetSoft Sales
Rep or Technical Support for details on CO-Processor cards available
for this configuration such as IBM ARTIC - real-time Interface Co-Proc.
Question: Can DOS EHLLAPI written programs be ported easily
to Windows Emulators avoiding costly Development delays....
Answer: DynaComm/Elite Version
3.51.02 provides DOS HLLAPI PASS-THRU to provide immediate conversion
from DOS to Windows to allow interim period for WIN Development.
Question: What is an economical means for implementing "DIAL-UP"
SDLC for 3270 access.
Answer: The most trouble free and
economical method is the selection of AUTOSYNC which is a feature
in HAYES OPTIMA Series MODEMs, AT&T DATAPORT and MEGAHERTZ Modems.
This Feature employs FIRMWARE in MODEMs that equals a SYNC SDLC
Adapter yet requires only COMx PORT connection.
Question: What is AdaptSNA RJE.
Answer: RJE is REMOTE JOB ENTRY and emulates IBM 3770 with
5 LUTYPE1 Logical Units for communicating with JES2, JES3, POWER
and SUPERTRACs VTAM Applications available on all MAINFRAME Systems.
This package provides Unattended Operator File Transfer Facility
with Compression and Compaction Support.
|